Diagnostic code · ARA0911

Behaviour callback threw

Behaviour construction or a lifecycle callback threw. The runtime disables the entire behaviour type until the next successful reload, not just the affected entity. Other types continue; writes already made by the callback are not transactionally rolled back.

Common causes

  • An exception in construction, OnSpawn, OnReload, OnTick or OnFrame.
  • A presentation cache was assumed to survive recreation during reload.

Fixes

  • Fix the reported exception and reload the module to re-enable the behaviour type.

  • Rebuild transient caches after recreation and keep persistent values in ECS-backed properties or components.

  • Code: ARA0911

  • Constant: script::BEHAVIOUR_FAULT

  • Reported by: ara-script, Ara.Runtime