Diagnostic code · ARA0904
Compile server unavailable
The compile-server connection failed, the process exited, or a requested module image did not arrive. Existing code is not replaced. Hot reload cannot progress while the connection is unavailable; an exited server requires the host to restart.
Common causes
- The compile server crashed, could not start, or lost its pipe connection.
- No initial module image arrived within the loader's three-minute timeout.
Fixes
Correct the reported process or connection failure, then restart the script host and its compile server.
Verify the configured compile-server executable or DLL exists and uses the expected .NET installation; inspect server output for a stalled compilation.
Code:
ARA0904Constant:
script::COMPILE_SERVERReported by: ara-script, Ara.Host